Set the following parameters on the machine
Press Mode button, the different options gets displayed
Press 9 to get the Special Parameter page
Press 1 to General parameter to set the communication parameter settings
P0 Baudrate
: 2400
P1 Databit
: 7
P2 Parity
: Even
P3 Stopbit
: 2
P605
: 00010000 (1: DNC activate)
Set the following parameters on the PC
General settings
Machine name
MCH-1
Control system
Fagor 8025
Machine ID
01
Time out (sec)
5
Control program start
M82
Control program end
M30
Is DNC required
Yes
DNC settings
Port Number
COM2 (or any free COM port)
Baud rate
2400
Data bits
7
Parity
Even
Stop bits
2
Handshake
Hardware
Filter null characters
Yes
Transmit settings
Transmit directory
Specify folder to store programs to be sent to machine from PC
Wait period at start of transmission
10.0
Wait period after transmitting program
5.0
Size of transmit packet
0
Delay period after each packet
0
Wait for XON before transmitting program
No
Drip feed
Off
Transmit comments?
Yes
Comment start character
(
Comment end character
)
Translation mode for CR
Transmit as CR
Translation mode for LF
Transmit as LF
Program start string
Program end string
^3^

 
Receive settings
Receive directory
Specify folder to store programs coming from machine
Wait period before receiving program
45.0
Wait period after receiving program
5.0
Transmit XON before transmitting program
No
Auto compare and save
Yes
Acknowledgements and errors
Transmit descriptive messages
Translation mode for CR
Ignore
Translation mode for LF
Save as CRLF
Acknowledgement error message start
%76
(MESSAGE FROM PC)
Acknowledgement error message end
Ignore control characters other than CR-LF
Yes
To set the PC in the Drip feed mode
Drip feed is not available on this controller.
Cable connection
If the PC has 9 pin connector

If the PC has 25 pin connector